Alternátor

Generátorová sada

Firstofall,theconceptofgeneratorset:Generátorová sadareferstopowergenerationequipmentthatcanconvertmechanicalenergyorotherrenewableenergyintoelectricalenergy.

Generally,ourcommongeneratorsetsareusuallydrivenbythefollowing:steamturbine,waterturbineorinternalcombustionengine(gasolineengine,dieselengineandothergenerators),windenergy,solarenergy,biomassenergy,oceanenergy,etc.Themarketfordieselgeneratorsisthelargest,mainlyduetothelargecapacityofdieselgenerators,whichcanoperateinparallelandhavealongcontinuouspowersupplytime,andcanalsooperateindependently.Itdoesnotoperateinparallelwiththeregionalgridandisnotaffectedbygridfailures.ReliabilityHigher.Especiallywhenthecommonlyusedcommercialpowerinsomeareasisnotveryreliable,usingdieselgeneratorsasabackuppowersourcecannotonlyserveasanemergencypowersource,butalsothroughreasonableoptimizationofthelow-voltagesystem,someofthemoreimportantloadsatordinarytimescanbecutoff.Whenused.Therefore,itiswidelyusedinengineering.

Klasifikace

Therearemanyformsofgenerators,buttheirworkingprinciplesarebasedonthelawofelectromagneticinductionandthelawofelectromagneticforce.Therefore,thegeneralprincipleofitsconstructionis:useappropriatemagneticandconductivematerialstoformmagneticcircuitsandcircuitsthatconductelectromagneticinductionwitheachothertogenerateelectromagneticpowerandachievethepurposeofenergyconversion.

Theclassificationofgeneratorscanbesummarizedasfollows:

GeneratorDCgenerator,ACgeneratorsynchronousgenerator,asynchronousgenerator(rarelyused)

Alternatorcanalsobedividedintosingle-phasegeneratorandthree-phasegenerator.

Struktura

Generatorsareusuallycomposedofstators,rotors,endcoversandbearings.

Thestatoriscomposedofastatorcore,wire-wrappedwindings,abaseandotherstructuralpartsthatfixtheseparts.Thefunctionofthestatoristogeneratealternatingcurrent.

Rotor se skládá z jádra rotoru (nebo magnetického pólu, magnetického třmenu) vinutí, ochranného krytu, středícího kroužku, kluzného kroužku, ventilátoru a rotujícího hřídele. Funkce rotoru generuje magnetické pole. Je instalován uvnitř statoru.

Theprincipleisthatthestatorandtherotorofthegeneratorareconnectedandassembledbythebearingandtheendcover,sothattherotorcanrotateinthestatorandcutthemovementofthemagneticlinesofforce,therebygeneratinganinducedelectricpotential,whichisledoutthroughtheterminalandconnectedtotheIntheloop,acurrentisgenerated.

Zásada

Usingtheprincipleofelectromagneticinductioninwhichtheelectricpotentialisinducedbythecuttingofmagneticlinesofforce,themechanicalenergyoftheprimemoverisconvertedintoelectricalenergyoutput.Thesynchronousgeneratoriscomposedoftwoparts:astatorandarotor.Thestatoristhearmaturethatgenerateselectricity,andtherotoristhemagneticpole.Thestatoriscomposedofanarmatureironcore,athree-phasewindinguniformlydischarged,abaseandanendcover,etc.Therotorisusuallyahiddenpoletype,consistingofanexcitationwinding,anironcoreandashaft,aguardring,andacenterring.Theexcitationwindingoftherotorisenergizedwithadirectcurrenttoproduceanearlysinusoidaldistributedmagneticfield(calledtherotormagneticfield),anditseffectiveexcitationmagneticfluxintersectswiththestationaryarmaturewinding.Whentherotorrotates,themagneticfieldoftherotorrotatesatthesametime,witheachrevolution,themagneticlinesofforcesequentiallycuteachphasewindingofthestator,andathree-phaseACelectricpotentialisinducedinthethree-phasestatorwinding.Whenthegeneratorisrunningwithasymmetricalload,thethree-phasearmaturecurrentiscombinedtoproducearotatingmagneticfieldwithasynchronousspeed.Theinteractionbetweenthestatormagneticfieldandtherotormagneticfieldproducesabrakingtorque.Fromthesteamturbine/waterturbine/gasturbine,theinputmechanicaltorqueovercomesthebrakingtorquetoperformwork.

Instalace

Tostartthedieselgeneratorsetwithelectricity,thestepsare:checkwhethertheelectricshockcontactofthestartermotorandelectromagneticoperatingmechanismisgood.Checkwhetherthepowercordiscorrect.Checkwhetherthereisdirtoroxidationonthebatteryterminal,whichshouldbepolishedclean.Firstcheckwhethertheelectro-hydraulicproportionofthestartingbatteryiswithintherangeof1.240~1.280.Iftheproportionislessthan1.180,itindicatesthatthebatteryisinsufficient.

Theinstallationandinspectionstepsofthealternatorareasfollows:

Wheninstallingthegenerator,ensurethatthecoolingairinletisunobstructed,andavoidtheexhaustedhotairfromenteringthegeneratoragain.Ifthereareshuttersontheventilationcover,thewindowshouldfacedowntomeettherequirementsoftheprotectionlevel.Forthemechanicalcouplingofsingle-bearinggenerators,specialattentionshouldbepaidtotheuniformairgapbetweenthestatorandrotor.

TheACgeneratoriscoupledwiththedieselgenerator,andtheparallelismandconcentricityofthecouplingarerequiredtobelessthan0.05mm.Inactualuse,therequirementcanbeslightlylower,about0.1mmorless,toolargereturnaffectsthenormaloperationofthebearing,resultingindamage,andthecouplingshouldbefixedwithpositioningpins.Thecouplingconditionshouldberetestedbeforeinstallation.

ThereareU,V,W,Nmarksontheterminalofthegeneratoroutletbox,whichdoesnotmeanthattheactualphasesequencedependsonthedirectionofrotation.UVWisprintedonthecertificatetoindicatetheactualphasesequencewhenrotatingclockwise,andVUWistheactualphasesequencewhenrotatingcounterclockwise.

Whentheslidingbearinggeneratoriscoupled,theheightofthecenterofthegeneratorshouldbeadjustedslightlytothecenterofyourdieselengine,sothattheweightoftheflywheelonthedieselenginewillnotbetransferredtothegeneratorbearing,otherwiseitwillgenerateelectricityThebearingofthemachinewillbeartheweightoftheflywheel,whichisnotconducivetotheformationoftheoilfilmoftheslidingbearing,resultinginheatgenerationandevenburningofthebearing.Noheavyobjectscanbecarriedonthecouplingofthistypeofgenerator.

Iftheneutralpointofeachgeneratorinthepowersupplysystemisconnectedtoeachother,ortheneutralpointofthegeneratorisconnectedtotheneutralpointofthetransformeranditsload,theneutrallinewillgooutwhentheunitisrunningNeutralcurrentat3timesthefrequency.Therefore,theneutralcurrentofthegeneratormustbemeasuredundervariousloadconditionsthatmayoccurduringoperation.Inordertopreventthegeneratorfromoverheating,theneutralcurrentmustnotexceed50%ofthegenerator'sratedcurrent.Theneutrallinepoweristoolarge,andaneutrallinereactorshouldbeinstalledontheneutrallinetolimitit.

Accordingtotheschematicdiagramorwiringdiagram,selecttheappropriatepowercableandusecopperconnectorsforwiring.Afterthecopperconnectorandthebusbararetightened,thelocalgapatthejointshouldnotbegreaterthan0.05mm,Thedistancebetweenthewiresisnotmorethan10mm,andthenecessarygroundingwiremustbeinstalled.

Specifikace pro použití

(1)Thegroundpolarityofthebatterymustbethesameasthatofthealternator.Theconsequenceofnotfollowingthespecificationisthatthediodewillbedamagedduetothelargecurrentdischargeofthediode.

(2)Whenthesixdiodesoftherectifiertubeareconnectedtothestatorwinding,itisabsolutelyforbiddentouseameggeror220VACpowersupplytochecktheinsulationofthealternator.Otherwise,itiseasytocausethediodetobreakdownandbedamaged.

(3)Aftertheengineisturnedoff,theignitionswitchshouldbeturnedoff.Iftheflameisnotturnedoffintime,thebatterywillcontinuetodischarge,whichwillaffectthemagneticfieldandshortenthebatterylife.

(4)Whenthealternatorisrunning,thefiretestmethodcannotbeusedtocheckwhetheritisgeneratingelectricity.Otherwise,itiseasytodamagethediodeandelectroniccomponents.

(5)Thegroundformoftheregulatorandthealternatormustbethesame,otherwisethealternatorwillnotbeabletooutputvoltageduetonomagneticfieldcurrent.Andthevoltagelevelofthetwoshouldbethesame,otherwisethechargingsystemcannotworknormally.

(6)Itisfoundthatthealternatorisnotgeneratingelectricityorthechargingcurrentissmall,andthefaultshouldbeeliminatedintime,andthewireconnectionbetweenthealternatorandthebatteryshouldbefirm.Otherwise,itiseasytodamagethediodeandelectroniccomponents.

(7)Whenthealternatorisinstalledontheengine,thecenterofthepulleygrooveofthealternatorshouldbealignedwiththecenterofthepulleygrooveoftheengine,andtheappropriateV-belttightnessshouldalsobeset.

(8)Při instalaci klínového řemenu silně vypáčte přední kryt alternátoru. V opačném případě se součásti pod tlakem poškodí.

Úkon

Krok

1.Přípravky

Disconnectthehigh-voltageswitchinthepowerdistributionroom,andturnontheisolatingswitchtogenerateelectricityLocation.

1.Turntheisolatingswitchofthegeneratorroomtothepowergenerationposition.

2.Checkthecoolingwater,lubricatingoil,andfuelstorageconditionsofthegenerator,andreplenishitintimeifanyshortageisfound.

3.Checkwhethertheconnectingparts,fastenersandoperatingpartsareloose,fallingoffandstuck.Whethertheconnectionofeachwireisfirm,correctandingoodcontact.

4.Openthecontrolcabinetunderthegeneratoroperationscreen,closethestartswitch,andwaitforthedisplaytobepowered.Pressthepageupanddownkeystoviewtherelatedoperationrecordsofthegenerator,andifanyabnormalsituationisfound,dealwithitimmediatelyandgetreadyforpowergeneration.

Za druhé, startandrun

1.Pressthestartbuttontostartthegenerator,andpayattentiontowhetherthereismechanicalnoise,abnormalvibration,etc.atthesametime.

2.Duringoperation,theoperatorcloselymonitorsthevoltage,frequency,current,powerfactor,oiltemperature,oilpressure,watertemperature,chargingcurrent,speedandotherinstrumentindicationsandchangesofthegeneratorsetthroughtheinstrument.Whenthespecifiedvalueisexceeded,checkandtakemeasuresintime,andthencontinuetorunafterreturningtonormal.

3.Theemergencystopbuttononthecontrolpanelisonlyusedinemergencysituations.Afterpressingthebutton,thegeneratorwillstopimmediately,andanaudibleandvisualalarmwillbeissuedatthesametime.

4.Afterthegeneratorisrunningnormally,turnonthemainswitchofthegeneratorset(low-voltageairswitch),andthegeneratorwillsupplypowertotheelectricload.

3.Zastavení

1.Afterthemainspowerisnormal,graduallycutofftheloadanddisconnectthemainswitchofthegeneratorset(low-voltageairswitch).

2.Underno-loadconditions,graduallyreducethespeedtoidlespeed,andstoptheengineagainwhenthewaterandoiltemperatureofthedieselenginedropsbelow70°C.

3.Disconnectthestart-upcontrolpowersupply,andswitchtheisolationswitchtothemainspositionaccordingtotheoperatingsequence.

Metoda

Ruční provoz

(1) Zkontrolujte práci před spuštěním:

1. Zapněte sílu.

2. Zkontrolujte, zda jsou následující položky normální:

(1)Hladina vody v nádrži

(2)Hladina motorového oleje a dieselového oleje

(3)Napětí baterie

(4) Hladina vody v baterii

3.Checkthecontrolpanel,switchthemainswitchtothestopposition,closethedetectionswitch,andwhenthedisplayisnormal,turnonthedetectionswitch,Eachmetershoulddisplayzero,andtheindicatorlightshowsshutdown.

(2) Spuštění

1.Switchthemainswitchtothemanualstartposition,thegeneratorshouldstartimmediately,andtheindicatorlightshowsnormal.

2.Observevariousinstrumentsonthecontrolpanel,andtheyshouldoperatenormally.

3.Pokud potřebujete pracovat se zátěží, zavřete vypínač výstupu.

(3) Vypnutí

1.Firstcutofftheback-endloadandthenturnoffthepoweroutputswitch.

2.Po pěti minutách chodu naprázdno přepněte hlavní vypínač do polohy stop.

3.Aftercheckingthateverythingisnormal,switchthemainswitchtotheautomaticstartposition,andclosethepoweroutputswitch.

Automatický provoz

(1)Pleaserefertomanualoperationforinspectionworkbeforestarting,butafterinspection,switchthegeneratortoautomaticstartstateandcloseitPoweroutputswitch.

(2) Spuštění:cutoffthepowersupplyofTaipowerandobservewhetheritstartsautomatically.

(3) Vypnutí:TurnonthepowersupplyofTaipowerandobservewhetheritautomaticallyswitchesthepowersupplyandautomaticallyshutsdown.

Tři, nouzové vypnutí

(1)Intheeventofanemergency,whenthegenerator'sownprotectiondevicerefusestostart,emergencyshutdownshouldbeperformedandthemainswitchshouldbeswitchedtotheoffposition.

(2)Aftertheemergencyshutdown,performacomprehensiveinspectionofthegeneratorimmediatelyandresumenormaloperationassoonaspossible.

Poznámka:

1.No-loadoperationofthegeneratorshallnotexceedfifteenminutes.

2.Po spuštění generátoru zkontrolujte hladinu vody, hladinu oleje, hladinu nafty, napětí baterie a kapalinu baterie generátoru, aby se udržoval v normálním stavu.

3.Anoperationrecordshallbemadeforeachdetectionorautomaticstart-upoperation.

Údržba

Běžná údržba

No-loadtestmachineonceaweek,runningtime10-15minutes,inordertofindtheproblemintimeandensurethatthebatteryhassufficientcapacityForthegeneratortostart.

1.Beforemaintenance,theautomaticairswitchofthegeneratorshouldbecutoff,themainswitchshouldbeplacedinthestopposition,andthepositiveandnegativepowercordsofthebatteryshouldbefoldofftoconfirmthatthegeneratorcannotbestarted.

2.Checkthebatteryelectrolytelevel,ifitisinsufficient,addsulfuricacidsolutionordistilledwateraccordingtoitsconcentration.

3.Calculatethecumulativeoperatingtimeofthegeneratorsincethelasttimeitwasraised.Theairfiltershouldbecleanedevery50hours,andtheoilfilter,dieselfilter,andwaterfiltershouldbereplacedevery250hours.Filterelement.

4.Checkwhethertheunitisleakingwateroroil,andcleanthegeneratorbody.

5.Connectthebatterypowercordandconnectorsproperly,andthetestfailureindicatorlightsshouldallbeon.

6. Zkontrolujte, zda je zemnící vodič v pořádku.

7.Checktheoperatingconditionoftheexhaustfanintheengineroom,andwhetherthedieseloilissufficienttorunforeighthours.

8.Checkwhetherthecoldwaterlevelandengineoillevelarenormal.

9.Afterthemanualtestmachinerunsnormally,turnontheautomaticairswitchofthegenerator,andswitchthemainswitchtotheautomaticstartposition,performasimulatedpowerfailuretest,andobservetheautomaticstartofthegenerator.

10.Runthegeneratorwithloadforonehour,andobservewhethertheinstrumentindicatorsandtheunitareoperatingnormally.

11.Vyplňte provozní záznamy a záznamy o údržbě.·

Technická údržba

Dieselgeneratorsetscanbedividedintotwotypesaccordingtotheirusageconditions:oneisbasedonmainspower,andtheotherisbasedonpowergeneration.Themachineisthemainpowersupplydevice.Thereisabigdifferenceintheusagetimeofthegeneratorsinthetwocases.Themaintenanceofdieselgeneratorsisgenerallydeterminedbytheaccumulatedhoursofstartingup.Thefirstpowersupplymethodmentionedaboveonlytestsforafewhourspermonth,suchasaccumulatedtotwoorthreetechnologies.Technická údržbaaftermaintenancehoursistoolong.Therefore,itshouldbeflexiblygraspedaccordingtothespecificsituationandtimelytechnicalmaintenancecaneliminatetheundesirablephenomenaofthemachineassoonaspossible,ensurethattheunitisingoodcondition,andextendtheservicelifeofthemachine.Therefore,inordertomakethedieselengineworknormallyandreliably,thetechnicalmaintenancesystemofthedieselenginemustbeimplemented.Thetechnicalmaintenancecategoriesaredividedinto:

Za prvé, první úroveň údržby (denně nebo týdně)

2.Údržbová kontrola úrovně 2 (každých 250 hodin nebo jeden měsíc)

Level3maintenanceinspection(every1500hoursorhalfayear)

Poznámka:1.Level3maintenance","Mediumrepairandmaintenance"and"overhaulandmaintenance"shouldbecompletedbyaprofessionaldieselgeneratormaintenancecompany.

2.Thestandbygeneratorshouldbeturnedonandrunforabout10minutesonaregularbasistoevaporatethemoistureinthedieselenginebodytopreventmoisture.,Anti-corrosion,etc..

(1),první úroveň údržby

Zkontrolujte hladinu oleje

Usethedieselengineoildipsticktochecktheoillevel.InordertogetaccurateTheoillevelshouldbeshutdownfor15minutesandcheckwhentheoilreturnstotheoilpan.Theoillevelshouldbematchedwiththeoriginaloilpan.Keeptheoillevelasclosetothehigh"H"markaspossible.

Warning:Neveroperatethedieselenginewhentheoilmarkislowerthanthelowmark"L"orhigherthanthehighmark"H"(ifnecessary,addengineoilofthesamequalityandgradeinthedieselengine).

Zkontrolujte chladicí systém

Keepthecoolingliquidfilleduptotheworkingsurface,checkthecoolingliquidleveleverydayoreverytimebeforestartingthemachine,analyzethereasonofthecoolingliquidconsumption,andcheckthecoolingliquidlevel,onlyafterthecoolingsystemiscooled.

Zkontrolujte připojení vstupního potrubí

Zkontrolujte připojení vstupního potrubí,whethertheclampisloose,whetherthehoseiscracked,perforatedorworn,whetherthereisahosebreakorForotherdamages,tightentheclamporreplacepartsasneededtoensurethattheairintakesystemiswellsealedandthatallairpassesthroughtheairfilter.

Vizuální kontrola

CheckifthereisoutsideairLeakage,leakageofcoolantoroil.Tightenthescrewconnections,joints,etc.orreplacethegasketasneeded.Checktheoildipstickforeachfuelingpipecovertoseeifitistightlytightened.

Zkontrolujte poškození

Checkthefuelsystem,etc.,includingtheerrorinvestigationorbumpsofthefuelpump,andcheckallconnectionsforleakageordamage.

Zkontrolujte hnací řemen

Inspectwhetherthefan,waterpump,chargerbeltisdamagedorloose.Ifthebuckleisdamaged,replaceitwithanewone.Andadjustthetightness.Ifnecessary,askaprofessionaltechniciantoadjust.

Záležitosti při údržbě

1.Tlak mazacího oleje je nízký.

2. Nedostatečný výkon.

3.Teplota oleje chladicí kapaliny je vysoká.

4. Nadměrná spotřeba chladicí kapaliny, oleje a paliva.

5. Zvuk motoru je abnormální, barva kouře je abnormální a výfukové potrubí kouře je červené.

Poznámky při použití falešného zatížení

1. Proces načítání 25 %, 50 %, 75 %, 100 %.

2.Upravte skutečný použitý výkon.

3. Běžte jednu hodinu při plném zatížení.

4.Observetheoutputparametersofthedieselengineatalltimesduringtheloadingprocess.