Преглед
Waterflowindicatorsaredividedintotwocategories:impellertype;floatingballtypenickname(throughimpellermirror,impellermirror,straightfloatmirror,floatmirrorLiquidflowobserver,flowindicator,flowmonitor,single-tubestraight-throughflowsightglass)isastraight-throughsightglass,whichisanecessaryaccessoryforobservingtheflowofthemediuminthepipeline.Thesightglassisusedinindustrialproductionequipmentsuchaspetroleum,chemicalindustry,chemicalfiber,medicine,food,etc.Itcanobservetheflowreactionofliquid,gas,steamandothermediaatanytime.Itisanindispensableaccessorytoensurenormalproduction.Waterflowindicatorsincludethreadedwaterflowindicators,weldedwaterflowindicators,flangedwaterflowindicators,saddle-typewaterflowindicators,andsaddle-typewaterflowindicators.
Thewaterflowindicatorcanalsobeusedinautomaticsprinklersystems.Itcanbeinstalledonthemainwatersupplypipeorthehorizontalmainpipetogiveanelectricalsignalofwaterflowinasmallareaofacertainsubregion.ThiselectricalsignalcanbeSenttotheelectriccontrolbox,butusuallynotusedasacontrolswitchtostartthefirepump.
One.Model
Тогава псевдоним на модела на индикатора за воден (масло) поток SG-YL (ZGA-1; ZGA-2; ZGA-3; ZGA-4 тип работно колело SJ-Y Тип работно колело наблюдател SJ-ZT прозорци за прав поток)
Псевдоним на модела на плаващ индикатор (GBA-1GBA-2GBA-3GBA-4тип топкаZBA-1ZBA-2ZBA-3ZBA-4(тип плаваща топка)
SG-II прав тип
SG-III трипътен тип
SG-BB тип люлка
SG-BLтип стъкло
SG-ZZ тип указател
SG-NZ тип обратно спиране
Модел SGEqualtoSJ
1. Преглед:
Suitableforawiderangeofindustriessuchasblastfurnacecoolingsystem,powerplantwatercirculationsystem,water(oil)pumpindicatingsystem,lubricationsystem,automaticsprinklersystem,etc.application.
2. Определение:
Anecessaryaccessoryforobservationinvarioussystemsorforconvertingwater(oil)flowsignalsintoelectricalsignalsinthesystem.
3.Основни параметри
1)Максималното работно налягане на индикаторите за воден поток е съответно 0,25/0,6/1,0/1,6/2,5/4,0MPa
2) Номинален диаметър
Номинален диаметър с резба/заварка DN6-DN80(G1/8-G3)
NominaldiameterofflangetypewaterflowindicatorisDN15-DN600
4.Технически изисквания
1) Максимално работно налягане
Максималното работно налягане на индикатора за воден поток зависи от калибъра: 0.25/0.6/1.0/1.6/2.5/4.0MPa
2) Забавяне на изпълнението
Thedelaytimeofthewaterflowindicatorwithdelayfunctionshouldbeadjustable.
Thedelaytimemeasuredbythewaterflowindicatortestshouldbewithintherangeof2s-90s.
3) Работен цикъл
Thewaterflowindicatoristested,after500cyclesofaction,theactionshouldbesensitiveandresetquicklyduringthetest.
4) Устойчивост на корозия
Thewaterflowindicatorissubjectedtothecorrosiontestaccordingtothestandard.Afterthetest,anypartofthewaterflowindicatormustnotshowcorrosiondamagesuchascracksthataffecttheperformance.Afterthetest,itshouldgothroughthe6.8sensitivitytest,andthetestresultshouldmeetthestandardrequirements.
5) Твърди неметални материали
Aftertheairagingtest,thetestpieceshallnotbebent,creeped,crackedorotherwisedamagedthataffectsthefunctionofthewaterflowindicator.Ifthebladeismadeofpolyethylenematerialandhastheabilitytowithstandenvironmentalstresscracking,thebladeshouldbefreeofcracksafterthetest.
6) Устойчивост на удар
Afterthree6.8Jenergyimpacts,theremustbenoloosepartsthathindertheactionofthewaterflowindicator.
Afterthetest,theshellofthewaterflowindicatorshouldbechecked.Iftheshellisbrokenanddoesnotaffecttheactionofthewaterflowindicator,itisqualified.Iftheshellisusedtopreventdustormoisture,andtheshellisbroken,thewaterflowindicatorisnotqualified.
7) Устойчивост на вода на еластични неметални уплътнения
Thewateragingtestofelasticnon-metallicgasketsiscarriedout,exceptforO-rings.Afterthetest,checkthegapbetweenthegasketandthefixturetoensurethatthereisnolooseness,adhesion,andbrittlenessorsoftnessofthegasket.
8) Чувствителност
Thewaterflowindicatorshouldbetestedforsensitivityaccordingtothestandard,andthetestresultsshouldmeetthefollowingrequirements:
aДебит по-малък от равен на 15,0L/Atmin, индикаторите за воден поток не трябва да алармират;
bСкоростът на потока на алармата трябва да бъде всяка стойност между 15,0L/min-37,5L/min и когато достигне 37,5L/min, трябва да се алармира;
bp>
c Дебитът на алармата не трябва да бъде по-голям от 37,5 L/min,
Диапазонът на изпитвателното налягане е между 0,14MPa-1,2MPa.
9) Загуба на хидравлично триене
Undertheconditionofthewatervelocityof4.5m/sinthetestpipeline,thepressurelosscausedbythehydraulicfrictionofthewaterflowindicatorshallnotexceed0.02MPa.
10) Устойчивост на воден удар
Thewaterimpacttestiscarriedoutaccordingtothestandard,anditshouldberesetquicklyafterbeingimpactedbywater.Andasensitivitytestshouldbecarriedoutafterthetest,andthetestresultshouldmeetthestandardrequirements.
11) Устойчивост на водно налягане
Водно налягане под 2,4 MPa за 5 минути, не трябва да има пукнатини, течове, постоянна деформация или повреда.
12) Капацитет на претоварване
Whenthewaterflowindicatoristestedinaccordancewiththestandard,itscomponentsmustnotbeburntduetooverheating,pits,orcontactbonding.
13)Withstandvoltagecapabilityandinsulationresistance
(1)Thewaterflowindicatorshallbetestedforthewithstandvoltagecapabilityaccordingtothestandard.Underthespecifiedtestvoltage,betweenthefollowingpartsWithstandvoltage60s±5swithoutbeingbrokendown.
aBetweenallmovingpartsandstaticmetalparts(includingthehousing);
bMovingpartsofcircuitsthatworkunderdifferentvoltagesanddifferentfrequencies.
(2)Thewaterflowindicatormeasurestheinsulationresistance,andtheinsulationresistancebetweenthefollowingpartsshouldbegreaterthan2MΩ.
aWhenthecontactisopen,betweentheincomingandoutgoingwiresofthesamepole;
bWhenthecontactisclosed,betweenthelivepartsofdifferentpoles,thecontactandthecoilandthecontrolBetweencircuits;
cBetweeneachlivepartandthemetalbracket(includingthehousing).
5.Ключови точки на конструкцията и монтажа
1)Generallyinstalledonthehorizontalbranchmainpipeoneachfloororbranchmainpipeinacertainarea.
2)Itshouldbeinstalledhorizontally,andtheinclinationshouldnotbetoolargetoensurethatthebladesaresensitive.Thereshouldbestraightpipeswith5timesthelengthoftheinstallationpipediameterbeforeandafterthewaterflowindicator.Payattentiontothewaterflowdirectionandindicatorwheninstalling.Thearrowsareconsistent.
3)Thesignalvalveshouldbeinstalledonthepipelinebeforethewaterflowindicator,andthedistancefromthewaterflowindicatorshouldnotbelessthan300mm.
4)Thewaterflowindicatorissuitableforinstallationonpipeswithadiameterof50-150mm.
6.Изпълнителен стандарт
1) Продуктов стандарт
1.Индикатор за воден потокструктураматериал:
Bodymaterial | Въглеродна стомана и неръждаема стомана, мед |
Материал за дограма | Закалено боросиликатно стъкло,quartzglass,aluminumsilicateglass |
Закалено боросиликатно стъкло | устойчиво налягане2.5MPa температурна устойчивост≤200℃ |
Кварцово стъкло | Pressureresistance10MPa,temperatureresistance≤1000℃ |
алумосиликатно стъкло | Pressureresistance6.4MPa,temperatureresistance≤450℃ |
Уплътнителен материал | Нитрилен каучук, политетрафлуоретилен |
II.Поддръжка и поддръжка на стъклени витрини
1.Theimpellersightglassisusedtoobservetheflowreactionequipmentofliquid,gas,steamandothermedia.Thewindowglassshouldbekeptcleananddust-free.
2.Thewindowglassoftheimpellersightglassissuitablefordamage,sobecarefulwheninstallingthesightglass.
3.Thetemperatureandpressureresistanceofthesightglasshascertainlimitations,dependingontheactualsituation.
Thefollowingprovidesthephysicalexperimentparametersofthenationalstandardglassmanufacturingprocess:
Temperatureresistance:temperedborosilicateglass≤200℃,quartzglass≤1000℃,алумосиликатно стъкло≤450℃
p>
Pressureresistance:temperedborosilicateglasssheet≤2.5MPa,quartzglasssheet≤10.0MPa,алумосиликатно стъкло≤6.4MP
4,allowrapidtemperaturechange<60℃,glassduetotemperaturedifferenceGreatlycauserupture.
Стандарт за проверка на стъкло: Проектиране, производство и приемане се отнасят до "Ръководство за химически тръбопроводи" и HGJ501-502-86 "Прозорец за наблюдение на налягането".
"Автоматична спринклерна система Част 7: Индикатор за воден поток" GB5135.7-2003
Диаграма и инструкции за разлагане
Awaterflowindicator,Itischaracterizedinthatitincludesavalvebody(1),apairofsteps(6)aresymmetricallyformedontheupperandlowersidesofthevalvecavity(5)ofthevalvebody(1),andtheleftandrightsidesofthevalvebody(1)extendrespectivelyThereisapipesection8;apairofsealingrings(4)arerespectivelyarrangedonthestep(6);apairofobservationwindows(2)arerespectivelylocatedonthesealingring(4),eachwithablindhole(10);Apairofobservationwindowfixingcovers (3) са поставени съответно на прозореца за наблюдение (2) и фиксирани с тялото на клапана (1); механизъм за индикатор на потока е поставен в кухината на клапана 5, който включва вал на саротора (15), Ротор (19), лопатки (14) и чифт гнезда на вала (12), двата края на вала на ротора (15) са поставени в отворите на вала (13) на вала (13) и гнездото на вала е наклонен върху ротора върху вала (15), лопатките (14) са удължени върху ротора (19) и чифт гнезда на вала (12) са поставени съответно в глухите отвори (10).